Rơ le an toàn

ReLy
Product family ReLy
Rely on safety relays from SICK
  • Safety relays for monitoring ESPE and safety switches
  • Up to PL e (EN ISO 13849), SIL3 (IEC 61508)
  • 2 safety outputs, fast response time of 10 ms
  • Slim housing
  • Plug-in terminals
  • Diagnostics via status LEDs and application diagnostic outputs
UE10-4XT
Product family UE10-4XT
Contact expansion for all safety relays
  • Contact expansions enable four additional safety outputs for evaluation units in the safety relays product family group
  • 4 safety outputs, 2 application diagnostic outputs
  • Feedback path for external device monitoring (EDM)
  • Coded plugs for all slots
UE11-4DX
Product family UE11-4DX
Time-delayed contact expansion for all safety relays
  • Contact expansions enable four additional safety outputs for evaluation units in the safety relay product family group
  • 4 safety outputs, 2 application diagnostic outputs
  • Predefined time delays
  • Feedback signal for external device monitoring (EDM)
  • Coded type for all plug-in positions
UE12-2FG
Product family UE12-2FG
Minimum required space with a maximum of contact outputs
  • Ideal for applications with opto-electronic protective devices and safety controllers with OSSD outputs
  • Fast response time of 10 ms
  • Compact design
  • 2 contact outputs
  • Up to 20 contact outputs via cascading
  • Feedback path for external device monitoring (EDM)
  • Screw-type terminals or plug-in screw-type terminals
  • Coded plugs for all slots
UE10-3OS
Product family UE10-3OS
The universal output expansion module
  • Ideal for applications with opto-electronic protective devices and safety controllers with OSSD outputs
  • Output expansion for a safe processing of OSSD output signals
  • 3 safety outputs, 1 application diagnostic output
  • Feedback path for external device monitoring (EDM)
  • Coded plugs for all slots
UE43-2MF
Product family UE43-2MF
Optimal monitoring of safety switches and emergency stop pushbuttons
  • Evaluation unit for emergency stop pushbuttons and safety switches
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • Discrepancy time monitoring is possible
  • 2 safety outputs, 1 application diagnostic output
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE43-3MF
Product family UE43-3MF
Complete monitoring of safety switches and emergency stop pushbuttons
  • Evaluation unit for emergency stop pushbuttons and safety switches
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • Discrepancy time monitoring is possible
  • 3 safety outputs, 1 application diagnostic output
  • Manual or automated reset
  • External device monitoring (EDM)
UE42-2HD
Product family UE42-2HD
Safety relays for two-hand controls
  • Evaluation unit for two-hand controls Type III C, in accordance with EN 574
  • Discrepancy time 500 ms
  • 2 safety outputs, 1 application diagnostic output
  • Monitoring of the external actuators possible
  • External device monitoring (EDM)
  • Coded plugs for all slots
UE23-2MF
Product family UE23-2MF
Application-specific relay for safety switches and emergency stop pushbuttons
  • Ideal for the connection of emergency stop pushbuttons and safety switches
  • 2 safety outputs, 1 application diagnostic output
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE43-3AR
Product family UE43-3AR
Fast monitoring of safety switches
  • Evaluation unit for safety switches
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • 3 safety outputs, 1 application diagnostic output
  • Automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE43-4AR
Product family UE43-4AR
Safety relay with four safety outputs for monitoring safety switches
  • Evaluation unit for safety switches
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • 4 safety outputs
  • Automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE44-3SL
Product family UE44-3SL
Compact safety relays for applications with mechanical locking switches
  • Ideal for the evaluation of safety switches with mechanical interlocking
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • 2 N/O contacts for a direct integration into a machine environment
  • 1 N/O contact for magnetic release, time delayed up to 30 s
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE48-3OS
Product family UE48-3OS
Safety relay with 3 safety outputs for all common safety applications
  • Ideal for the evaluation of emergency stop pushbuttons, safety switches, safety light curtains, safety laser scanners, and safety pressure sensitive mats
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • 3 safety outputs
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE45-3S1
Product family UE45-3S1
Safety stop via time delay
  • Ideal for evaluating emergency stop pushbuttons and safety switches
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • 2 N/O contacts for direct integration into a machine environment
  • 1 N/O time for stop category 1 applications, time delayed up 30 s
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
UE48-2OS
Product family UE48-2OS
Safety relay for all common safety applications
  • Ideal for the evaluation of emergency stop pushbuttons, safety switches, safety light curtains, safety laser scanners, and safety pressure sensitive mats
  • Cross-circuit detection and sequence monitoring at the dual-channel input signal
  • 2 safety outputs, 1 application diagnostic output
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
Speed Monitor
Product family Speed Monitor
Optimal safety protection in maintenance mode
  • Zero-speed and drive monitoring
  • 4 safe semiconductor outputs
  • PL e (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (EN 62061)
  • Maximum input frequency of 2 kHz
  • Adjustable monitoring limit/monitoring frequency from 0.1 to 9.9 Hz or 0.5 to 99 Hz
  • 2 application diagnostic outputs for failure and status display
  • Diagnostic LEDs
UE10-2FG
Product family UE10-2FG
The ideal solution to integrate relay outputs
  • Ideal for applications with opto-electronic protective devices and safety controllers with OSSD outputs
  • Fast response time of 10 ms
  • Compact design
  • 2 contact outputs
  • Feedback path for external device monitoring (EDM)
  • Screw-type terminals or plug-in screw-type terminals
  • Coded plugs for all slots
UE23-3MF
Product family UE23-3MF
Connection solution for safety switches and emergency stop pushbuttons
  • Ideal for the connection of emergency stop pushbuttons and safety switches
  • 3 safety outputs, 1 application diagnostic output
  • Manual or automated reset
  • External device monitoring (EDM)
  • Coded version for all slots
Standstill Monitor
Product family Standstill Monitor
Standstill monitoring without additional sensors
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
  • 1 application diagnostic output normally open
  • PL e (EN ISO 13849), SIL3 (IEC 61508), SILCL 3 (EN 62061)
  • Maximum motor supply voltage 690 V
  • Adjustable voltage threshold and standstill period
UE402
Product family UE402
Functionality upgrade for C4000
  • C4000 Standard: Bypass, operating mode switching, PSDI
  • C4000 Advanced: Bypass, operating mode switching, PSDI
  • C4000 Fusion: Bypass, operating mode switching
  • C4000 Palletizer: Bypass, operating mode switching
  • C4000 Entry/Exit: Bypass, operating mode switching
UE403
Product family UE403
Muting switching amplifier for M4000 Advanced
  • Connection of 2 to 4 muting sensors, external muting lamp, reset and override control switch, belt stop signal
  • Functions: Concurrence monitoring, monitoring of the total muting time, sensor gap monitoring, sensor testing, partial blanking, end of muting via the ESPE, integrated override
UE401
Product family UE401
Evaluation unit for L4000 Systems single-beam photoelectric safety switches
  • Restart interlock
  • External device monitoring (EDM)
  • Cascading single-beam photoelectric safety switches
  • Fast response time
  • Slim housing
Hotline: 024 2219 8822